|
BMC Atrium CMDB Data Model |
BMC.CORE:BMC_BaseElement
|
+--BMC.CORE:BMC_SystemComponent
|
+--BMC.CORE:BMC_HardwareSystemComponent
|
+--BMC.CORE:BMC_NetworkPort
Properties |
Name | Value | Scope | Options |
namespaceName
|
BMC.CORE | None | None |
classId
|
BMC_NETWORKPORT | None | None |
FormName
|
BMC.CORE:BMC_NetworkPort | None | None |
Exposure
|
usedVisible | TOSUBCLASS=false | OVERRIDABLE=false |
Attributes Summary |
Data type | Name and description |
decimal
|
ActiveMaximumTransmissionUnit
Specifies the active or negotiated maximum transmission unit (MTU) that the port can support. |
enumeration
|
AutoSense
Specifies a Boolean value indicating whether the port can automatically determine the speed or other communications characteristics of the attached network media. |
enumeration
|
FullDuplex
Specifies a Boolean value indicating whether the port is operating in full duplex mode (carrying signals in both directions). |
enumeration
|
LinkTechnology
Specifies the link technology used by the network port. |
decimal
|
MaxSpeed
Specifies the maximum bandwidth of the port in bits per second. |
character
|
NetworkAddresses
NetworkAddresses is an historic artifact and is not used. Specifies the list of strings specifying the network addresses for the port. |
character
|
PermanentAddress
Specifies the network address hard-coded into the port. This address can be changed by firmware upgrade or software reconfiguration. For an Ethernet port, the value is the MAC address separated by colons (for example, 00:1C:B3:09:85:15). |
character
|
PhysicalDescription
Attribute that specifies the physical description of the port, for example, "slot3" or "port4." |
enumeration
|
PortType
Specifies the type of port. |
decimal
|
Speed
Specifies the current bandwidth of the port in bits per second. For ports that vary in bandwidth or for ports whose speed cannot be accurately estimated, Speed contains the nominal bandwidth. |
decimal
|
SupportedMaximumTransmissionUnit
Specifies the maximum transmission unit (MTU) that the port can support. |
Attributes inherited from class BMC.CORE:BMC_HardwareSystemComponent |
PNPDeviceID, PowerManagementCapabilities, PowerManagementSupported, SystemAvailability |
Attributes inherited from class BMC.CORE:BMC_SystemComponent |
isVirtual, SystemClassId, SystemName |
Attribute Detail |
decimal
ActiveMaximumTransmissionUnit
Name | Value | Scope | Options |
FieldId |
301041800
|
None | None |
attributeId |
OB000874CD4B4FoD2cQAAj29CwFAMA
|
None | None |
namespaceName |
BMC.CORE
|
None | None |
enumeration
AutoSense
Name | Value | Scope | Options |
FieldId |
301041400
|
None | None |
attributeId |
OB000874CD4B4FoD2cQA7jy9CwEgMA
|
None | None |
namespaceName |
BMC.CORE
|
None | None |
ValueMap |
0;1
|
None | None |
Values |
Yes;
No
|
None | TRANSLATABLE= true |
enumeration
FullDuplex
Name | Value | Scope | Options |
FieldId |
301041300
|
None | None |
attributeId |
OB000874CD4B4FoD2cQA5Dy9CwEQMA
|
None | None |
namespaceName |
BMC.CORE
|
None | None |
ValueMap |
0;1
|
None | None |
Values |
Yes;
No
|
None | TRANSLATABLE= true |
enumeration
LinkTechnology
Name | Value | Scope | Options |
FieldId |
301041200
|
None | None |
attributeId |
OB000874CD4B4FoD2cQAxjy9CwDgMA
|
None | None |
namespaceName |
BMC.CORE
|
None | None |
ValueMap |
0;1;2;3;4;5;6;7;8;9;10;11
|
None | None |
Values |
Unknown;
Other;
Ethernet;
IB;
FC;
FDDI;
ATM;
Token Ring;
Frame Relay;
Infrared;
BlueTooth;
Wireless LAN
|
None | TRANSLATABLE= true |
decimal
MaxSpeed
Name | Value | Scope | Options |
FieldId |
301140000
|
None | None |
attributeId |
OB000D56BA2BA5qAfwQABCvqCAUgEA
|
None | None |
namespaceName |
BMC.CORE
|
None | None |
character
NetworkAddresses
Name | Value | Scope | Options |
FieldId |
301041600
|
None | None |
attributeId |
OB000874CD4B4FoD2cQA2jy9CwEAMA
|
None | None |
namespaceName |
BMC.CORE
|
None | None |
MaxLen |
64
|
None | None |
character
PermanentAddress
Name | Value | Scope | Options |
FieldId |
301041500
|
None | None |
attributeId |
OB000874CD4B4FoD2cQA0Dy9CwDwMA
|
None | None |
namespaceName |
BMC.CORE
|
None | None |
MaxLen |
64
|
None | None |
character
PhysicalDescription
Name | Value | Scope | Options |
FieldId |
301140100
|
None | None |
attributeId |
OB000D56BA2BA5ygfwQA_63qCAVwEA
|
None | None |
namespaceName |
BMC.CORE
|
None | None |
MaxLen |
255
|
None | None |
enumeration
PortType
Name | Value | Scope | Options |
FieldId |
530014600
|
None | None |
attributeId |
OBF00874CD4B4FoD2cQA2jy9CIEAM5
|
None | None |
namespaceName |
BMC.CORE
|
None | None |
Required |
true
|
None | None |
ValueMap |
0;1;2;3;4;5;6
|
None | None |
Values |
Other;
Unknown;
Ethernet;
FDDI;
Token Ring;
WAN;
Fibre Channel
|
None | TRANSLATABLE= true |
decimal
Speed
Name | Value | Scope | Options |
FieldId |
301139900
|
None | None |
attributeId |
OB000D56BA2BA5igfwQAN7XpCAUQEA
|
None | None |
namespaceName |
BMC.CORE
|
None | None |
decimal
SupportedMaximumTransmissionUnit
Name | Value | Scope | Options |
FieldId |
301041700
|
None | None |
attributeId |
OB000874CD4B4FoD2cQA[Dy9CwEwMA
|
None | None |
namespaceName |
BMC.CORE
|
None | None |
Name | Superclass | Reference CI Class |
|
BMC Atrium CMDB Data Model |